18 XR500/XR100 User’s Guide Arming and Disarming
Arming an All/Perimeter System
1. Enter your 4-digit user code. The keypad displays PERIM
ALL.
2. Select PERIM to arm the Perimeter area only.
3. Select ALL to arm both the Perimeter and Interior areas.
4. The keypad displays zones that have been bypassed prior to
arming and zones that are now in a faulted condition.
5. At this point you can force arm or bypass any faulted zones.
A zone that is force armed is restored into the system if it
later returns to normal. A bypassed zone remains bypassed
until the system is disarmed. See steps 5a through 5d.
5a. If a problem exists on any zones, the zone name and
problem display followed by: OKAY BYPASS STOP.
5b. Select OKAY to force arm the zone(s) before arming.
5c. Select BYPASS to bypass the zone(s) before arming.
5d. Select STOP to stop the system from arming. Correct
the zone problem(s) and return to step 1.
6. The keypad displays PERIMETER ON if only the perimeter is
being armed and ALL SYSTEM ON if both the perimeter and
interior are being armed.
7. The keypad next displays EXIT: ## INSTNT and begins to
count down the number of seconds remaining for you to
exit. When the delay expires, all zones are armed.
8. You can select INSTNT while EXIT: ## INSTNT displays to
immediately arm all zones and make them instant. The
keypad displays INSTANT. When you select INSTANT, any
entry/exit zone that trips immediately activates an alarm
and the exit delay countdown immediately stops.
9. When the system is fully armed, the keypad displays
PERIMETER ON for perimeter arming and ALL SYSTEM ON for
perimeter and interior arming.
All/Perimeter System Disarming
Disarming: While the system is armed, you can only enter the
premises through an entry/exit delay door without causing an
alarm. After opening the door, the keypad sounds a prewarn tone
to remind you to disarm the system. You must disarm the system
before the prewarn tone expires or an alarm on the door zone will
occur.
During the prewarn tone, the keypad displays ENTER CODE:. Enter
your user code to disarm the system.
Schedules: If you have programmed schedules for your system and
a user code is entered outside of a schedule, the keypad displays
INVALID TIME. This lets the user know that they are disarming
outside of their authorized time.
Alarm Display: After disarming, the keypad dis plays any zones
that tripped or any transmission problems that occurred dur ing
the armed period. All burglary zones are then dis armed and any
by passed zones are automatically reset.
Disarmed Message: The keypad displays ALL SYSTEM OFF after the
system disarms.
Central Sta tion Report: A report of the system disarming can be
transmitted to the central sta tion. This is optional and can be
programmed for you at any time.

Table of Contents

Other manuals for DMP Electronics XR100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DMP Electronics XR100 and is the answer not in the manual?

DMP Electronics XR100 Specifications

General IconGeneral
BrandDMP Electronics
ModelXR100
CategorySecurity System
LanguageEnglish

Related product manuals