XR500/XR100 User’s Guide 29User Menu
Using the Panic Zone Test (XR500N/E Only)
1. Access the User Menu.
2. Press COMMAND until SYSTEM TEST? displays.
3. Press any Select key. The keypad displays SYSTEM PANICS.
4. Select PANICS.
5. The Panic Zone Test begins automatically and the keypad
displays TRIPS: END.
During the Panic Zone Test, trip each panic zone (or button)
by pressing and holding the panic for 1 to 2 seconds.
Note: You do NOT have to hold the panic for 2 seconds in normal
mode. The Panic Zone Test takes additional time to report
when the system is in test mode.
Each time you trip a panic zone, the display number
increments and the keypad buzzer sounds for two seconds.
The number of panic zones tripped constantly displays until
the test ends or no panic zone activity has occurred for 20
minutes.
6. Select END to stop the Panic Zone Test.
7. PANIC TEST OKAY displays when the Panic Zone Test is
completed and all zones tested OK.
8. When the Panic Zone Test ends and a zone failed (did not
trip) during the test, the keypad displays the zone name and
number and the buzzer sounds for one second. Press the
COMMAND key to display the next failed zone.
Note: During the Panic Zone Test, any zones that fail are not
sent to the receiver unless pre-programmed at installation
to be sent.
Note: Your system may be programmed to limit the Panic
Zone Test to only be performed during the Area 32, Shift 4
schedule.
User Proles
Add,delete,orchangeUserProles,thatdenetheauthorityof
eachusercodein thesystem.Severalcharacteristicsdenethe
authorityofeachUserProlewithinthesystem.Alwaysmakesure
thatatleastoneadministratorinyoursystemhasaprolewithall
authorities and all areas.
InAll/PerimeterorHome/Sleep/Awayoperation,UserProleswill
not display in the User Menu. When adding User Codes, use the
defaultproles1through10.RefertotheUserProlesChart.
InHome/Sleep/AwaywithGuestoperation,theUserProlesoption
does not display in the User Menu but when adding User Codes, enter
a prole number1 through 9 for themain housesystem, proles
11-19 for the Guest 1 house system, and proles 21-29 for the
Guest2housesystem(XR500only).Proles2-9willdefaulttohave
Arming/Disarmingforalleightareas,whileproles12-19and22-29
only have Arm/Disarm assigned to Guest 1 and Guest 2 respectively.
Proles1,11,and21donothaveanyArming/Disarmingauthority
assigned.RefertotheUserProlesChart.
Prole Number - Eachprolemay be assigneda unique number
from 1 to 99.
Prole Name-Eachprolemaybeassigneda32-charactername.
TheProleNumberisthedefaultname.
Area Number - Each prole may be assigned specic areas of
thesystem for arminganddisarming. When proles1to 98 are
created,NOareasareassignedbydefault.Thedefaultforprole
99isALLareasassigned.Prole99ispredenedinthesystemby
the factory. In an XR500 Series system you can assign areas 1 to
32. In an XR100 Series panel you can assign areas 1 to 8.
Access Area Number - Eachprole may be assigned door access area
assignments.Defaultforprole1to98isNOareasassigned.Defaultfor
prole99isALLareasassigned.Prole99ispredenedatthefactory.

Table of Contents

Other manuals for DMP Electronics XR100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DMP Electronics XR100 and is the answer not in the manual?

DMP Electronics XR100 Specifications

General IconGeneral
BrandDMP Electronics
ModelXR100
CategorySecurity System
LanguageEnglish

Related product manuals