26 XR500/XR100 User’s Guide User Menu
Zone Status
Displays a list of armed, bypassed, or alarmed zones. Also allows
you to check the status of individual zones. Zone Status can be
used to give you a list of zones by category or display the current
status of an individual zone number. The four categories are:
• ArmedZones-zonesthatarecurrentlyarmed.
• BypassedZones-zonesthatarecurrentlybypassed.
• AlarmedZones-zonesthathavegoneintoalarmduringthe
current or previ ous armed period.
• Number-enterthenumberofanyzonetocheckitsstatus.
Using the Zone Status Function
1. Access the User Menu.
2. Press COMMAND until ZONE STATUS? displays.
3. Press any Select key to display ARM BYPS ALR NBR.
4. Select ARM for a list of zones that are currently armed. You
can scroll through the list by pressing the COMMAND key.
5. Select BYPS for a list of zones that are currently bypassed.
6. Select ALR for a list of zones that have gone into alarm
during the current or previous armed period.
7. Press NBR and ZONE NO: - displays.
8. At the ZONE NO: - option, enter the zone number you want
to check and press COMMAND. The zone number and name
display followed by the zone status. For example, a zone
status for zone 1 might be BACK DOOR - OKAY.
Below is a list of the zone status displays:
-OKAY = the zone is in a normal condition
-BYPAS = the zone is bypassed
-BAD = the zone is in a bad or faulted condition
9. After displaying the zone status, ZONE: - returns for you to
enter another zone number.
Browser Feature
If you are unsure of the zone number or description, refer to
Appendix B at the back of this guide for a diagram showing you
how to use the built-in Zone Status browser.
Bypass Zones
Allows you to bypass a zone prior to arming.
Bypassing is usually done when a zone cannot be restored to
normal.Asignicantbenetofbypassingazoneistoallowazone
in a faulted or bad condition to be bypassed so arming can occur.
The faulted zone can be serviced the next day.
A zone can be bypassed only while it is disarmed. Fire, panic,
emergency, and supervisory type zones are always armed, so they
can never be manually bypassed.
Bypass Zones can also be used to reset a zone that has been
bypassed and restore it back into the system.
When Bypass Zones is selected, a report can be transmit ted to
your central station.
During arming, when choosing to bypass a zone or device, there
may be a pre-programmed maximum number of zones (up to 8)
that can be bypassed in an area. This limit is programmed at
installation.
Using the Bypass Zones Function
1. Access the User Menu.
2. Press COMMAND until BYPASS ZONES? displays.
3. Press any Select key. The keypad displays
ZONE: - RST BYPS.
4. To Bypass a zone, enter the zone number and select BYPS.
The zone number automatically disappears and a new zone
number can be entered. Refer back to step 3.
5. To Reset a zone, enter the zone number and select RST.

Table of Contents

Other manuals for DMP Electronics XR100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DMP Electronics XR100 and is the answer not in the manual?

DMP Electronics XR100 Specifications

General IconGeneral
BrandDMP Electronics
ModelXR100
CategorySecurity System
LanguageEnglish

Related product manuals