Digital Monitoring Products XR200/XR2400F Programming Guide
36
14.10 Swinger Bypass
YES allows the zone to be swinger bypassed by the panel according to the
specifications programmed in Swinger Bypass Trips and Reset Swinger Bypass. The
Bypass condition will be displayed in the keypad Status List. Selecting NO disables
swinger bypassing for this zone.
How it works
If within one hour, a zone trips the total number of times AS specified in Swinger
Bypass Trips, the panel bypasses it until the following conditions occur; the area in
which the zone is assigned is disarmed, the zone is manually reset through the
Bypass Zones? keypad User Menu function, the zone remains normal for one hour
and the Reset Swinger Bypass is YES.
If the zone trips fewer than the specified times within one hour, the bypass trip
counter returns to zero and the process must be repeated.
A report of the swinger bypass is sent to the receiver if Bypass Reports is YES.
14.11 Prewarn Addresses
At the start of the entry delay, all keypad addresses selected here display ENTER
CODE:-. If you want the prewarn to sound at all eight addresses, leave the
default as shown.
To delete an address, press the matching number on the keypad. To disable
prewarning at all keypads, press a top row key to clear the addresses shown.
Press the COMMAND key when the address selection is complete.
14.12 Entry Delay
Select the entry timer for this zone. Entry timers 1 to 4 are programmed in
System Options.
14.13 Zone Retard
When you select YES, the zone operates with the zone retard delay. The retard
functions only in zone short conditions.
The zone must remain shorted for the full length of the retard delay before the
panel recognizes its condition. If you select NO, the zone operates without a
retard delay.
14.14 Presignal Addresses
You can enable any combination of keypad addresses to sound a presignal tone
during the time a zone is in retard delay. The presignal tone silences when the
zone restores or the retard delay expires.
To enable a presignal address, press any top row Select key followed by the
number of the keypad address. You can enable the presignal for all eight keypad
addresses. To disable a presignal address press the matching number digit again.
Press the COMMAND key when the address selection is complete. The Presignal
prompt is only displayed when Retard is selected as YES.
14.15 Fast Response
Select YES to provide a zone response time of 167ms. Select NO to provide a
normal zone response time of 500ms. Zones 100 to 299 have a fixed response
time of 200ms and do not display this prompt.
RETARD NO YES
PRESGNL: NONE
FAST RSP NO YES
ENTRY DELAY: 1
PREWARN: 12345678
SWGR BYP NO YES
14 - ZONE INFORMATION

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DMP Electronics XR200 and is the answer not in the manual?

DMP Electronics XR200 Specifications

General IconGeneral
BrandDMP Electronics
ModelXR200
CategoryControl Panel
LanguageEnglish

Related product manuals