Digital Monitoring Products XT30/XT50 Installation Guide
18
COMPLIANCE
False Alarm Reduction Programmable Options
ANSI/SIA CP-01-2010
26.1 Shipping Defaults and Recommended Programming
SIA CP-01 FEATURE
PARAGRAPH # AND
DESCRIPTION
DMP PROGRAMMING
GUIDE LT-0981
SECTION #
REQUIREMENT RANGE
SHIPPING
DEFAULT
RECOMMENDED
PROGRAMMING*
4.2.2.1 Exit Time 8.6 Exit Delay
Required
(Programmable)
45 sec. - 250 sec.
60
Seconds
60 Seconds
4.2.2.2 Progress
Annunciation
13.14 Prewarn Address Allowed
Individual keypads
may be disabled per
zone
All
keypads
enabled
All keypads enabled
4.2.2.3 Exit Time Restart 8.6 Exit Delay Required Option
For re-entry during
exit time
Enabled Enabled
4.2.2.5 Auto Stay Arm on
Unvacated Premises
8.17 Occupied Premise
- See Install Guide
Required Option
(except for
remote arming)
Occupied Premise NO/
YES option
Enabled
Enabled Yes
for Residential
Applications
4.2.4.4 Exit Time and
Progress Annunciation/
Disable - for Remote Arm
Not Available on
Remote Arming
Allowed Option
Progress Annunciation
Always disabled for
Remote Arming
Not
Available
Remote Arming not
allowed for CP-01
installations.
4.2.3.1 Entry Delay(s) 8.5 Entry Delay
Required
(Programmable)
30 sec. – 240 Sec. **
30
Seconds
At least 30 Seconds **
4.2.5.1 Abort Window –
for Non-Fire Zones
3.3 Transmit Delay Required Option
Disable by zone or
zone type
Enabled
NT DY EX
Zone
Enabled
4.2.5.1 Abort Window
Time – for Non-Fire
Zones
3.3 Transmit Delay
Required
(Programmable)
20 sec., 30 sec., or
40 sec. **
30
Seconds
At least 20 Seconds **
4.2.5.1.2 Abort
Annunciation
3.3 Transmit Delay Required Option
Annunciate that no
alarm was transmitted
Yes Yes
4.2.5.4.1 Cancel
Annunciation
Always Enabled - Not
Programmable
Required Option
Annunciate that
a Cancel was
transmitted (S49)
Always
Enabled
Yes
4.2.6.1 & 4.2.6.2 Duress
Feature
User Code + 1 =
Ambush Code Not
Available
Allowed Option
No 1 + derivative of
another user code/no
duplicates with other
user codes
Code +1
Always
Disabled
Not Programmable
4.3.1 Cross Zoning 13.16 Cross Zone Required Option
Yes/No Zone
Programming
No
Enabled using two or
more programmed
zones
4.3.1 Programmable
Cross Zoning Time
8.7 Cross Zone Time Allowed 4 sec. - 250 sec. 0 Seconds
Per walk path in
protected premises
4.3.2 Swinger Shutdown
Not Available — Always
On
Required 1-6 trips 2 trips 2 trips
4.3.2 Swinger Shutdown
Disable
13.13 Swinger Bypass Allowed
For non-police
response zones
Yes Enabled (all zones)
4.3.3 Fire Alarm
Verication
13.5 Zone Type Required Option FV Type Zone No
Yes as required (unless
sensors can self verify)
4.5 Call Waiting Cancel
3.17 First Telephone
Number
Required Option
Include *70P in
Telephone Number
Disabled
Enabled if user has
call waiting
4.6.3 System Test 17.5 Walk Test Allowed
Test all protection
devices
N/A N/A
4.6.5 Communications 17.5 Walk Test Not Allowed N/A N/A N/A
* Programming at installation may be subordinate to other listed requirements for the intended application.
** For listed Installations, combined Entry Delay and Transmit Delay should not exceed 1 minute.

Table of Contents

Other manuals for DMP Electronics XT30

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DMP Electronics XT30 and is the answer not in the manual?

DMP Electronics XT30 Specifications

General IconGeneral
BrandDMP Electronics
ModelXT30
CategoryControl Panel
LanguageEnglish

Related product manuals