XT30/XT50 Installation Guide Digital Monitoring Products
19
COMPLIANCE
26.2 Call Waiting
The Call Waiting default setting is disabled. To cancel the Call Waiting feature, program * (star) 7 0 P
(pause), the standard telephone code prex that cancels call waiting, into the telephone number string.
Cancel Call Waiting for telephone lines that have Call Waiting operational on the telephone line. See the
XT30/XT50 Programming Guide.
Caution: A call waiting cancel programmed on a non-call waiting telephone line, would prevent
communication to the central station.
26.3 Entry Delay
Only use Entry Delay 1. Do not use Entry Delay 2. See the XT30/XT50 Programming Guide.
26.4 Local Bell
All non-re zones such as Night, Day, Exit, Aux1 and Aux 2 must be programmed for local bell enabled with a
bell cuto time set to a minimum of 6 minutes to provide a cancel window of 5 minutes or greater. This does
not apply to manually operated zone types such as Panic and Emergency.
26.5 Minimum Installation Requirements
SIA CP-01-2010 minimum system installation requirements include an XT30 or XT50, a local Bell, and o
premise DACT communication to an SCS-1R receiver plus one of the following compatible keypads.
7060, 7063, 7070, 7073, 7160, 7163, 7170, or 7173 Thinline™ keypads
7060A, 7063A, 7070A, or 7073A Aqualite™ keypads
7360 or 7363 Thinline™ Icon keypads
7872 or 7873 Graphic Touchscreen Keypads