5.2.3. Oil exchange procedure
While the oil is still hot, exchange oil as fol-
lows:
¥
Take out the oil dip dipstick.
¥
Remove the drain valve from oil pan and
the drain plug form oil filter head, then
drain out the engine oil into a container.
¥
Reassemble the drain valve with the oil
pan and the drain plug with oil filter head
after draining out the engine oil.
¥
Refill with new engine oil at the oil filler
neck on the head cover and the lubricating
oil in accordance with the oil capacity of
the engine through oil filler. Be careful
about the mixing of dust or contaminator
during the supplement of oil. Then confirm
that oil level gauge indicates the vicinity of
its maximum level.
¥
For a few minutes, operate the engine at
idling in order to circulate oil through lubri-
cation system.
¥
Thereafter shut down the engine. After waiting for about 10 minutes measure the quantity of
oil and refill the additional oil if necessary.