EasyManua.ls Logo

Doran 7000 - Digital Filter Setup Menu; Automatic Zero Tracking Setup Menu; Motion Aperture Setup Menu; Stability Indication Menu (Model 7000 Only)

Doran 7000
45 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Digital Filter Setup Menu
Avg Averaging mode
Determines the number of samples to average
A1 Auto averaging 1:1 when in motion A
weighted average filter displays each reading
when stable.
1 No averaging All readings displayed.
2 Fixed averaging 2 readings are averaged.
4 Fixed averaging 4 readings are averaged.
8 Fixed averaging 8 readings are averaged.
Automatic Zero Tracking Setup Menu
AZt
Automatic Zero Tracking Range
Small weights within the specified number of
divisions are automatically zeroed.
off Zero tracking is off. No automatic zeroing.
0.5 Zero tracking to within 0.5 division.
1 *
Zero tracking to within 1.0 division.
3 *
Zero tracking to within 3.0 divisions.
Motion Aperture Setup Menu
mA *
Motion aperture *
Determines how many divisions consecutive
readings must change before the scale is
considered in motion.
1 1 division change must be seen to enter motion.
3 3 division change must be seen to enter motion.
5 5 division change must be seen to enter motion.
Stability Indication Menu (Model 7000 only)
Stt *
Stability Indication * Not available on the 7000XL
Controls the display of scale motion.
on Enables motion indication by blanking the units
annunciators when motion is present .
off Deactivates the motion indicator.
18

Table of Contents

Other manuals for Doran 7000