Error messages:
Error Message What to Do or Check:
"ovr-Ld" Scale overload
The scale is in overload. The load on the scale
platform exceeds the scale capacity by more than
103%. Remove excess weight from scale
platform.
"grs-oL" Gross overload
The scale is in gross overload. The load exceeds
the scale ratings and might result in damage to the
scale. Remove excess weight immediately.
"SU 0 E" Startup zero error
The scale was not stable, or a weight in excess of
1.9% of full load was present on the platter when
the scale started. This error will only occur in
Legal for Trade applications. Remove the weight
and wait. The scale will zero once it becomes
stable.
"Err EP" EEPROM error
The nonvolatile memory has been corrupted by
transients or electrostatic discharge. Reenter the
scale parameters and recalibrate the scale (see
Section 4).
"rg. Err" Calibration range
error
During span or zero calibration, the scale input
was at an incorrect level. Press ZERO to clear
error. Then correct the input levels. See Section
5 for more detail.
"Err 1" Program ROM error
The program memory in the scale has become
corrupted. Have scale serviced by a qualified
scale repair technician.
"Err AO" Analog output
error.
The scale has been set up for the Option "R"
4-20ma analog output module when this option is
not present.
"Ldg 0" Loading zero.
The the scale is attempting to load power up zero.
This message will remain until scale is stable.
42