4. Unscrew the two thumb screws on the print head module until the entire print head
module can be rotated clockwise on the contact shaft.
The print head does not need to be removed. Mark the position of the print head on
the contact shaft if it is not against the inside wall or outside stop.
The gap sensor can now be easily accessed from above.
5. Clean the gap sensor with compressed air
6. After cleaning, return the print head module to its original position and retighten
the thumb screws. See "Cleaning the print head" on page 6 for specific directions.
7. Before switching on the device, check whether the print head cable is still properly
connected. If this is not the case, plug in the cable correctly.