28
A setting value of 50 means that all readings over 50 are considered product,
therefore the printer will consider the labels as the product, and the black bars will not
affect printing. A setting between the values of 30 and 60 is ideal for this application.
INTERF. PARAM.
Do not alter any of these settings within the interface parameters submenu without
consulting a service technician. Changing any of these settings can disrupt
communication between the printing computer and the printer. All of the parameters in
this section should be considered for service technician use only.
SYSTEM PARAMETERS
Foil end warning
Setting for a limit diameter for the ribbon roll. If the ribbon roll diameter falls below
the set value, the displayed message changes from
ONLINE X JOBS
to
FOLIE X JOBS
x.xx mm Setting range: 25.4 to 50.0 mm; Unit interval: 0.1 mm;
Default setting: 25.4 mm
Foil warn stop
Disabled (Default setting) Printer does not stop in case of a Foil end warning.
Enabled If a Foil end warning occurs, the printer will stop after the current label
and shows the status message. Press the online button to acknowledge the
message, then the feed button to continue printing.
Autom. dot check
Checks the print head for defective dots. The dot check can be carried out either after
powering on the printer or in print pauses between print jobs.
Continuous The dot check is carried out in pauses between print jobs. If a new
print job arrives before the dot check is done, the print job will be preferred. The
printer then interrupts the dot check and proceeds later with the next opportunity
at the last tested dot. The parameters Early dottest, Latest dottest, Dottestarea