30
Dottestarea to
Only displayed if SYSTEM PARAMETER > Autom. dot check = Continuous.
Upper border of the dot check area. The value sets the distance in mm to the left print
head end, looked at on the print head from above.
x mm Setting range: refer to Tab. 3; Unit interval: 1; Default setting: 0 mm
The value for "Dottestarea to" must be set higher than the value for "dottestarea
from"! (exception: value 0).
Print Interpret.
For Service Technician Use Only.
Character sets
For Service Technician Use Only.
Character filter
For Service Technician Use Only.
Light sens. type
The reflex photoelectric switch for labels with reflecting backings, or the normal
factory-fitted photoelectric switch for, must be defined according to the application.
Full Size Full Size photoelectric sensor (Adjustment range is the material width).
Reflex Reflex photoelectric sensor (for reflecting markings)
Punched Transparent photoelectric sensor (for gaps)
Head-sensor dist.
For Service Technician Use Only.
Sens. punch-LS
Sets the sensitivity of the material photoelectric switch.
xxx mm Setting range: 10 to 100%; Unit interval: 10% Default setting: 50%
Maximum sensitivity: 100%. for narrow gaps (perforations).
Minimum sensitivity: 1%. for clearly detectable gaps.
Too high a level of sensitivity can lead to gaps being detected which do not even
exist (on proofs, material thickness fluctuations, perforations etc.).