W2940305 Rev 07 8/2019 Dover Fueling Solutions 45
5.7.4.2 Resettable Electronic Totals (Statistics S01 & S02)
For units with the price display option, press <NEXT> after displaying the volume
totals to display the money totals.
Enter Statistics
Step IRC Command
V
olume
Display
Status
Display
1 Enter sign on
Press either <ENTER>, <1>, or <2>
depending upon access level
Note: If you only have operator access (2),
you cannot reset the totals.
PASS 1 [blank]
2 Enter your password
Type your password & Press
<ENTER>
PASS 2 [blank]
3 Re-enter your
password
Type your password again & Press
<ENTER>
[alternating
software
version & date]
F - -
4 Go to statistics entry
point
Press <DOWN>
[alternating
current trans.
counts for Side
A & Side B]
S - -
View Resettable Total -Side A Nozzle #1 (A1)
5 Go to Side A resettable
totals function
Type <1> & Press <ENTER>
- - - - - - S 01
6 Go to nozzle #A1 sub-
function
Press <ENTER> again
[totalizer A1
value]
1.11
Reset Total - Side A Nozzle #1 (A1) - to Zero (if you do not want to reset total, skip to Step #10)
7 Clear total Press <#> CLEAr totALS 1.11
8 Confirm clear Press <ENTER> PASS 1.11
9 Enter reset password Type <42> & Press <ENTER> - - - - - - S 01
Exit Statistics
13 Return to statistics
entry point
Press <CLEAR>
Note: if you are not resetting the totals,
press <ENTER> 3 times to exit statistics
- - - - - - S - -
14 Go to function level Press <UP>
[software ver.
& date]
F - -
15 Go to exit function Type <0> and Press <ENTER> - - - - - - F 00
16 Go to exit sub-function Press <ENTER> again 1 0.00
17 Clear display Press”#” [blank] 0.00
18 Exit and save changes Type <3> & then press <ENTER>
3 0.00
19 Exit configuration Press <ENTER> again
[alternating
CHAnGE
StorEd]
0.00