4 Technical manual | X-am
®
2800 / X-am
®
5800
Safety-related information
1 Safety-related information
The calibration certificate can be downloaded from
https://www.draeger.com/productioncertificates.
The manufacturer's certificate can be requested from Dräger.
1.1 Basic safety information
Before using the product, carefully read through these instructions for use, the
instructions for use provided with the associated products and the general
instructions for use for sensors (9023657).
Strictly follow the instructions for use. The user must fully understand and strictly
observe the instructions. Use the product only for the purposes specified in the
Intended use section of this document.
Do not dispose of the instructions for use. Ensure that they are retained and
appropriately used by the product user.
Only trained and competent users are permitted to use this product.
Comply with all local and national rules and regulations associated with this
product (e.g. IEC 60079-14, EN 60079-29-2, EN 45544-4, IEC 62990-2).
Only specialist, trained personnel are permitted to check, repair and maintain
the product as described in these instructions for use and the technical manual.
Further maintenance work that is not detailed in these instructions for use or in
the technical manual must only be carried out by Dräger or personnel qualified
by Dräger. Dräger recommend a Dräger service contract for all maintenance
activities.
Only use genuine Dräger spare parts and accessories when performing
maintenance work, or the proper functioning of the product may be impaired.
Do not use a faulty or incomplete product. Do not modify the product.
Notify Dräger in the event of any component fault or failure.
Substitution of components may impair the intrinsic safety of the product.
Electrical pairing with devices which are not listed in these instructions for use
should only be done following consultation with the respective manufacturers or
an expert.
1.2 Use in areas subject to explosion hazards
To reduce the risk of ignition of a flammable or explosive atmosphere, strictly
observe the following warnings:
Use in areas subject to explosion hazards
Devices or components for use in explosion-hazard areas which have been tested
and approved according to national, European or international explosion protection
regulations may only be used under the conditions specified in the approval and
with consideration of the relevant legal regulations. The devices or components
may not be modified in any manner. The use of faulty or incomplete parts is
forbidden. The appropriate regulations must be observed at all times when carrying
out repairs on these devices or components.

Table of Contents

Other manuals for Dräger MQG 02 0 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dräger MQG 02 0 Series and is the answer not in the manual?

Dräger MQG 02 0 Series Specifications

General IconGeneral
BrandDräger
ModelMQG 02 0 Series
CategoryGas Detectors
LanguageEnglish

Related product manuals