Horizon Compact Release 1.01.00 Wireless Ethernet Product User Manual – Volume 2
Required Action Steps
erase log Removes all entries from the events log
Sequence :
erase log
The system responds :
Erased log succcessfully.
Procedure 4-9
Performance Log
Required Action Steps
login using NOC account
Log in as a NOC account
get performance logging Returns the status of performance logging
Sequence :
get performance logging
The system responds :
Performance Logging has been :[enabled/disabled.]
set performance logging Allows you to enable or disable performance logging
Sequence :
set performance logging [on/off]
The system responds :
Performance Logging is :[on/off]
set performance log interval Sets the time interval between performance log updates
Sequence :
set performance log interval hh:mm:ss
Where hh is in hours, mm is in minutes and ss is in seconds. Note
that the maximum interval allowed is 24 hours and the minimum is
15 seconds. The default setting is 15 minutes. See
Table 4-2 for
log durations for different intervals.
The system responds :
The performance logging interval is set to: hh:mm:ss

Table of Contents