Network Management of Horizon Compact
135
Horizon Compact Release 1.01.00 Wireless Ethernet Product User Manual – Volume 2
Required Action Steps
get snmp traps Displays the list of traps available in the system.
Sequence:
get snmp traps press Enter
The system responds:
Trap# TrapName Enabled(Yes | No)
1 ColdStart No
2 WarmStart No
3 Link down No
4 Link up No
5 Explicit Authentication Failure No
6 AutoNeg Mismatched Duplex No
7 LossOfSignalLockFromDemod No
8 BerThresholdExceeded No
9 Mod PLL lock failure No
10 Mod loss of sync bytes No
11 Mod input FIFO overrun/underrun No
12 Mod input data inactivity No
13 SNR below threshold No
14 PLDRO lost lock No
15 Radio lost comm No
16 Radio mismatch No
17 IF Tx Synth Unlocked No
18 IF Rx Synth Unlocked No
19 TTY Session commenced No
20 TTY Session terminated No
21 RSL Below Threshold No
22 Dropped Frames Threshold exceeded No
23 Bandwidth Utilization Threshold exceeded No
24 Excessive Cable Loss No