Advanced Configuration Features
59
Horizon Compact Release 1.01.00 Wireless Ethernet Product User Manual – Volume 2
Required Action Steps
set air interface authentication
type
Sets the authentication type. This needs to be set to unique.
The default type is none.
Sequence:
set air interface authentication type [none, unique, group] press
Enter
where [none, unique, group] identifies the authentication type. Use
unique on this occasion.
The system responds:
AIR INTERFACE AUTHENTICATION type set to : unique
Set unique peer
authentication key <xxxx>
Sets the unique peer authentication key of the peer node with which
you wish to authenticate, generally the far-end unit.
Sequence:
set unique peer authentication key <xxxx> press Enter
where <xxxx> is the Unit Serial Number of the far-end unit
determined from the get hw inventory command performed earlier.
The system responds:
Unique Peer Authentication Key: xxxx.
Note: You will need to repeat this procedure for each unit.
NOTE:
Once the unique authentication key is set, you will need to verify the
authentication settings and set the authentication failure parameter
before saving the mib and resetting the system. See Procedure 3-11.
This concludes the steps to setting authentication to unique.