DragonWave Inc. 60
Horizon Compact Release 1.01.00 Wireless Ethernet Product User Manual – Volume 2
Procedure 3-11
Setting Group authentication
Perform this procedure to set group authentication using the CLI manager.
Required Action Steps
login Log in as a NOC user.
Set air interface
authentication type
Sets the authentication type. This needs to be set to group.
The default type is none.
Sequence:
set air interface authentication type [none, unique, group] press
Enter
where [none, unique, group] identifies the authentication type. Use
group on this occasion.
The system responds:
AIR INTERFACE AUTHENTICATION type set to : group
Set group authentication key Sets the group authentication key.
Sequence:
set group authentication key <xxxxxxxx> press Enter
where <xxxxxxxx> is a character string consisting of up to eight
characters that may be: 0 to 9, a to z, and A to Z but may not contain
any of the following: !@#$%^&*(,);:’”+-~
The system responds:
Group Authentication Key: xxxxxxxx.
Note: The <xxxxxxxx> is the unique eight-character string you have
assigned to be the group authentication key. You will need to repeat
this procedure for each unit in the group that uses the same group key.
NOTE:
Once the group authentication key is set, you will need to verify the
authentication settings and set the authentication failure parameter
before saving the mib and resetting the system. See Procedure 3-11.
This concludes the steps to set the group authentication key using the CLI manager