DragonWave Inc. 64
Horizon Compact Release 1.01.00 Wireless Ethernet Product User Manual – Volume 2
Required Action Steps
set RSL threshold alarm
settings
Sets the current settings for the Threshold Alarm for the Receive
Signal Level (RSL). Once the RSL Value Threshold is reached and
continues for the Time Limit duration then an alarm is raised.
Sequence:
set rsl threshold <rsl value> <timelimit> press Enter
Where
<rsl value> is the desired RSL value in integers, given in dBm.
<timelimit> is the desired time limit that the condition must occur
before the alarm is raised. Timelimit is in integers, given in number
of seconds
The system responds:
RSL threshold set to : <rsl value> dbm
RSL timelimit set to : <timelimit> secs
get snr threshold Returns the current signal to noise ration alarm threshold.
Sequence:
get snr threshold press Enter
The system responds:
SNR threshold set to : n
Where n is the current SNR threshold setting
set snr threshold Sets the SNR level below which a threshold alarm will be raised.
Sequence:
set snr threshold <snr value> press Enter
Where <snr value> is in dB and between 0 and 30
The system responds:
SNR threshold set to : n
Where n is the new SNR threshold setting