Advanced Configuration Features
65
Horizon Compact Release 1.01.00 Wireless Ethernet Product User Manual – Volume 2
Required Action Steps
get bandwidth utilization
threshold alarm settings
Displays the current settings for the Bandwidth Utilization Threshold
Alarm.
Sequence:
get bandwidth utilization threshold press Enter
The system responds:
Bandwidth utilization threshold set to : <value> % Bandwidth
utilization timelimit set to : <timelimit> secs.
Where
<value> is the current bandwidth utilization value expressed in
percentage
<timelimit> is the desired time limit that the condition must occur
before the alarm is raised. Timelimit is in integers, given in number
of seconds
set bandwidth utilization
threshold alarm settings
Sets the values for the Threshold Alarm for the Bit Error Rate (BER) as
calculated by the Horizon Compact modem. Once the BER Value
Threshold is reached and continues to remain between the Threshold
value and the hysteresis value, then an alarm is raised. Once the
value drops below the hysteresis value then the alarm is cleared.
Sequence:
set bandwidth utilization threshold <value> <timelimit> press
Enter
Where
<value> is the current bandwidth utilization value expressed in
percentage
<timelimit> is the desired time limit that the condition must occur
before the alarm is raised. Timelimit is in integers, given in number
of seconds. Default value is 10 seconds
The system responds:
Bandwidth utilization threshold set to : <value> % Bandwidth
utilization timelimit set to : <timelimit> secs.
get dropped frames threshold
alarm settings
Displays the current settings for the Dropped Ethernet Frames
Threshold Alarm.
Sequence:
get dropped frames threshold press Enter
The system responds:
Dropped frames threshold set to : <value> %
Dropped frames timelimit set to : <timelimit> secs.
Where
<value> is the current dropped frames value expressed in
percentage
<timelimit> is the desired time limit that the condition must occur
before the alarm is raised. Timelimit is an integer, given in number of
seconds