DragonWave Inc. 66
Horizon Compact Release 1.01.00 Wireless Ethernet Product User Manual – Volume 2
Required Action Steps
set dropped frames threshold
alarm settings
Sets the values for the Dropped Ethernet Frames Threshold Alarm.
As the Horizon traffic rate from the LAN side exceeds the programmed
limit, frames are dropped in order to maintain the limit.
Sequence:
set dropped frames threshold <value> <timelimit> press Enter
Where
<value> is the current dropped frames value expressed in
percentage
<timelimit> is the desired time limit that the condition must occur
before the alarm is raised. Timelimit is in integers, given in number
of seconds. Default value is 10 seconds.
The system responds:
Bandwidth utilization threshold set to : <value> % Bandwidth
utilization timelimit set to : <timelimit> secs.
save mib
Saves the MIB to RAM. Perform this command to save setting
changes to non-volatile memory.
Sequence:
save mib press Enter
The system responds:
MIB saved successfully.
This concludes the steps to configure Threshold Alarms for the Horizon Compact system using the CLI