Exiting the Local Diagnostic/Programming Mode
To exit the Local Diagnostic/Programming Mode, press the MENU key for 1-1/2 seconds.
The time and date display should reappear.
Displaying the ATEL Hardware Revision and Software Version
Press the MENU key for 1-1/2 seconds to enter the Local Diagnostic/Programming
Mode. The ATEL will alternately display its model number and its hardware revision/
software version. Press MENU for 1-1/2 seconds again to exit the Local Diagnostic/
Programming Mode.
Verifying a Key’s Function
The EMERGENCY, TONE, PAGE, and PROGRAM keys and the F1–F8 keys on an
ATEL can be reprogrammed to perform different functions. To determine the current
function of any key, follow the steps below.
1. Press MENU for 1-1/2 seconds to enter the Local Diagnostic/Programming Mode.
2. Press and release the key you want to verify. The key’s function appears on the
ATEL display and the feedback tone sounds.
3. Press MENU for 1-1/2 seconds to exit the Local Diagnostic/Programming Mode.
Programming the Dedicated Function Keys
The EMERGENCY, TONE, PAGE, and PROGRAM keys can be reprogrammed to dial a
different sequence. Operation of these dedicated function keys will differ from what is
described in this manual if the default settings are reprogrammed. The factory default
settings for the dedicated function keys are:
EMERGENCY 70
TONE 71
PAGE 72
PROGRAM 73
As you reprogram the function keys, write down their new functions in the chart provided
in Appendix B on page for future reference.
1. Press MENU for 1-1/2 seconds to enter the Local Diagnostic/Programming Mode.
2. Press the desired function key. The display will show a two-character code indicating
the function key (EM, TN, PG, or PR) accompanied by the current programmed dial
sequence and a flashing cursor.
continued
SCR+ Telephone Operation Manual
15
Local Diagnostic/Programming Mode