I/O Output Control 754, command, output no., #
(See ATEL at right for command
definitions.)
754, command (see below), output
no., #
0—off
1—on
2—momentary (one second)
OCC Output Control 764, command, OCC output no., #
(See ATEL at right for command
definitions.)
764, command (see below), OCC
output no., #
0—off
1—on
2—momentary (one second)
3—cycle (one second on, one second
off, continuous)
4—toggle (switch states)
Clear Error Codes 753, #, password 753, #, password
Notes:
Zone numbers—1 or more zones (01–32)
Room numbers—1 or more rooms entered according to the number of System digits (3, 4, or 5)
Source number—01–10
Tone number—01–32
Schedule numbers—1 or more schedules (01–32)
I/O output number—01–08 (if no entry, assumes all)
OCC output number—001, 002, 003, etc.
Password—4-digit System password