6.11.3 Table of machine-specific parameters of the DA82GA and 6F82FA controls
The values of the parameters listed below must be changed from their
pre-set values.
The values concerned (x) can be found in parameter sheet
9800 130014 PB52 or 9800 321009 PB52
(in the machine’s accessory pack).
Parameter
F-111
F-112
F-113
F-117
F-123
F-124
F-136
F-153
F-171 **
F-180 **
F-182 **
F-190
F-192
F-194
F-196
*
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
Name
upper limit of maximum rotation speed
starting bar-tack rotation speed
ending bar-tack r otation speed
rotation-speed stroke adjustment (DB2000)
bar-tack synchronisation time for ending bar tack
bar-tack synchronisation rotation speed for ending bar
tac k
thread-cut stitch backwards/forwards
holding power with the machine at a standstill
needle positions
number of reverse increments
handwheel reverse ON/OFF
thread cutter activation angle
activation delay for thread-tensioner release
activation delay for thread cutter
function of both thread tensioners on sewing-foot lift
367
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
* T = technician-level parameter, A = manufacturer-level parameter
** Not the 6F82FA control
Caution !
Great care must be taken w hen changing parameter values, as an
incorrectly-set drive control may damage the machine!
A master reset restores all parameters to their pre-set values. See
section 6.12.