EasyManua.ls Logo

DURKOPP ADLER 367 - EFKA 6 F82 FA Control System; 6 F82 FA Key Functions and Parameter Adjustment

DURKOPP ADLER 367
41 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6.11.3 Table of machine-specific parameters of the DA82GA and 6F82FA controls
The values of the parameters listed below must be changed from their
pre-set values.
The values concerned (x) can be found in parameter sheet
9800 130014 PB52 or 9800 321009 PB52
(in the machine’s accessory pack).
Parameter
F-111
F-112
F-113
F-117
F-123
F-124
F-136
F-153
F-171 **
F-180 **
F-182 **
F-190
F-192
F-194
F-196
*
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
Name
upper limit of maximum rotation speed
starting bar-tack rotation speed
ending bar-tack r otation speed
rotation-speed stroke adjustment (DB2000)
bar-tack synchronisation time for ending bar tack
bar-tack synchronisation rotation speed for ending bar
tac k
thread-cut stitch backwards/forwards
holding power with the machine at a standstill
needle positions
number of reverse increments
handwheel reverse ON/OFF
thread cutter activation angle
activation delay for thread-tensioner release
activation delay for thread cutter
function of both thread tensioners on sewing-foot lift
367
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
* T = technician-level parameter, A = manufacturer-level parameter
** Not the 6F82FA control
Caution !
Great care must be taken w hen changing parameter values, as an
incorrectly-set drive control may damage the machine!
A master reset restores all parameters to their pre-set values. See
section 6.12.
29