6.11.7 Setting parameters on the 6F82FA control
Changing technician-level parameter values
Entering the technician-level code number
–
Turn off the main switch.
–
All plugs must be plugged in to the sewing-drive control.
–
Press and hold down the “P”key.
–
Turn on the main switch. “Cod” appears in the display.
–
Release the “P”key.
–
Enter code no. 190.Pressthe“+”or“-” keys to alter the value of
the flashing digit. Press the “>>” key to move to the next digit.
–
Press the “E” key. The first technician-level parameter “100”is
displayed.
Selecting parameters and changing values
–
Press the “+”, “-” and “>>” keys to select the parameter.
–
Press the “E” key. The value of the selected parameter is
displayed.
–
The parameter value can be changed with the “ +” and “-”keys.
–
Press the “E” key to display the next parameter
or the “P” k ey to display the same parameter.
Saving changed parameter values
–
Press the “P” key to terminate programming.
–
Sew a complete seam, i.e. push the pedal forward and then fully
back. The change is saved.
–
If no seam is sewn, the change is lost.
–
Press the “P” key again to return to programming level.
Changing parameter values
Entering the manufacturer-level code number
–
Turn off the main switch.
–
All plugs must be plugged in to the sewing-drive control.
–
Press and hold down the “P”key.
–
Turn on the main switch. “Cod” appears in the display.
–
Release the “P”key.
–
Enter code no. 311 .Pressthe“+”or“
-” keys to alter the value of
the flashing digit. Press the “>>” key to move to the next digit.
–
Press the “E” key. The first manufacturer-level parameter
-“200” - is displayed
–
Continue as for “Selecting parameters and changing values”
Caution !
The changed parameter values are not saved unless a complete seam
is sewn after leaving programming level, i.e. the pedal is pushed
forwards and then all the way back. If the drive is switched off straight
after leaving programming level, the changes are lost.
33