Settings via the software
Operating Manual 512/532 Version 00.0 - 12/2013 47
Function display shows the parameter value.
2. Press the +/– Program buttons to select a different parameter.
3. Press the Ready button to confirm the parameter.
The button LED illuminates.
4. Press the +/– Function buttons to change values.
5. Press the Reset button to return a changed value to the original
value.
6. Press the Ready button to save a change.
The button LED goes out.
7. Press the Memory button.
The button LED goes out.
5.19.2 Editing parameters at the M2 level
Prerequisite:
Machine is in programming mode, Ready button LED is off.
1. Press and hold the Memory button for 6 s.
The controller beeps twice, the button LED lights up.
The Program display shows the parameter number, the
Function display shows the parameter value.
2. Press the +/– Program buttons to select a different parameter.
3. Press the Ready button to confirm the parameter.
The button LED illuminates.
4. Press the +/– Function buttons to change values.
5. Press the Reset button to return a changed value to the original
value.
6. Press the Ready button to save a change.
The button LED goes out.
7. Press the Memory button.
The button LED goes out.