5.24.3 Setting parameter U085 (Class 532)
With the button sewing machine, the parameter U085 must be set
after loading new software.
Prerequisite:
Machine is in programming mode, Ready button LED is off.
1. Press and hold the Memory button for 6 s.
The button LED illuminates.
2. Use the +/– Program buttons to set parameter number U085.
3. Press the Ready button.
4. Use the +/– Function buttons to enter a function value of 1.
5. Press the Select button.
5.24.4 Checking the software version
1. Press and hold the Memory button for 6 s.
The controller beeps twice, the button LED lights up.
2. Press the +/– Program buttons and select parameter U097.
3. Press the Ready button.
The current software versions are displayed:
M X.XX = Main program
P X.XX = Control panel
T X.XX = Servo motors
A X.XX = Seam appearances
4. Press the +/– Function buttons and check the respective
software version.
5. Press the Ready button.
6. Press the Memory button.
The button LED goes out.