Light barriers
Service Instructions 745-35-10 S/745-35-10 A - 02.0 - 04/2017 121
6. Press the  button.
 The flap clamp opens.
7. Press the  button.
 The needles are switched on.
8. Use the handwheel to turn the needles downward with the direction of 
rotation until they are approx. 2 mm above the sewing material.
Fig. 103: Setting the light barriers for automatic slant detection (2)
9. Insert the template (1) (straight pocket) such that line (4) points to the 
left needle and is parallel to the right transport clamp.
10. Press the  button.
 The flap clamp closes.
11. Fix the erect template (1) on the left in place on the clamp using a strip 
of adhesive tape (3).
12. Press the  button.
 The needles are switched off.
13. Use the handwheel to turn the needles to the top dead center against 
the direction of rotation.
14. Press the  button.
 The template (1) is scanned.
The display shows the scanned parameters. The scanned parame-
ters are automatically adopted by the control.
15. Press the  button.
 The flap clamp opens.
16. Remove the template (1).
(3) - Strip of adhesive tape
(4) - Line
(5) - Strip of adhesive tape
(6) - Line