Programming
274 Service Instructions 745-35-10 S/745-35-10 A - 02.0 - 04/2017
Multi test I/O
The display switches to Multi test I/O.
Fig. 236: Multi test I/O
To carry out an input and output test:
1. Select an input in the left area:
Inputs 745-35-10 S
(1) - Input
(2) - Increase selection by 1
(3) - Display of the selected input
(4) - Reduce selection by 1
(5) - Clear selection
(6) - Manual test On/Off
(7) - Automatic test On/Off
(8) - Output
S1 Needle thread monitor needle left
S2 Needle thread monitor needle right
S3 Folder down
S4 Folding device swiveled in
S5 Knife block swiveled in
S6 Light barrier for material removal / Cover monitoring
S7 Pedal in front
S8 Pedal back
S21 Light barrier for flap scan
S24 Second Light barrier for flap scan
S100 reference switch for sewing motor
S101 Reference switch transport clamp