318 Service Instructions 745-35-10 S/745-35-10 A - 02.0 - 04/2017
Error code 2000-2999: Error messages motors
2101 Step motor transport clamp
timeout reference
Faulty cable to the reference
switch
Reference switch defective
Replace the cable
Replace the reference switch
2102 Step motor transport clamp
overload
Blocked/sluggish, defective
Control defective
Fix blockage
Check the encoder cable and
replace, if necessary
Replace the step motor
2103 Step motor transport
Step motor transport clamp
(transport clamp) has step loss
Check seizing of the transport
clamp
2121 Transport clamp step motor:
Encoder plug (Sub-D, 9-pin)
not connected or defective
Encoder defective
Check the encoder cable
connection and replace encoder
cable, if necessary
2122 Pulse-wheel search time out Check connection cables
Check step motor for stiff
movement
2130 Step motor card defective Perform software update
p. 296
Replace the step motor card
Replace the control
2152 Step motor transport clamp
excess current
Replace the transport clamp step
motor
Replace the control
2153 Step motor transport clamp
excess voltage
Check the mains voltage
2155 Step motor transport clamp
overload
defective/seized up
defective
Control defective
Fix blockage/sluggishness
Replace the step motor
Replace the control
2156 Step motor transport clamp
overheat
Step motor transport clamp
seized up
Faulty step motor transport
clamp
Control defective
Eliminate seizing
Replace the transport clamp step
motor
Replace the control
Error code Symbol Meaning Remedial action