Safety of persons
• The system has its own power source when connected to the UPS (UPS battery). Consequently,
the power outlets may be energized even if the system is disconnected from the AC power source.
Dangerous voltage levels are present within the system.
Itshouldbeopenedexclusivelybyqualiedservicepersonnel.
• Theproductmustbeproperlygrounded,alwaysconnecttheearthwirerst
Product safety
• The ModularEasy connection instructions and operation described in the manual must be followed
in the indicated order. Disconnection and overcurrent protection devices shall be provided by others
for AC in/out circuits.
• CAUTION-Toreducetheriskofre,theunitconnectsonlytoacircuitprovidedwithbranchcircuit
overcurrent protection (please refer to the UPS User Manual for current rating).
The upstream circuit breaker must be easily accessible.
The unit can be disconnected from AC power source by opening this circuit breaker, and if still
connected to UPS, by previously shutting down the UPS (refer to the UPS User Manual)
• Check that the indications on the rating plate correspond to your AC powered system and to the
actual electrical consumption of all the equipment to be connected to the system.
• For PLUGGABLE EQUIPMENT, the socket-outlet shall be installed near the equipment and shall be
easily accessible
• Never install the system near liquids or in an excessively damp environment.
• Never let a foreign body penetrate inside the system.
• Never expose the system to direct sunlight or source of heat.
• If the system must be stored prior to installation, storage must be in a dry place.
• The admissible storage temperature range is -15ºC to +60ºC.
Special precautions
• The ModularEasy is designed to work with approved EATON UPS (contact your Eaton reseller for
more information).
• All repairs and service should be performed by AUTHORIZED SERVICE PERSONNEL ONLY.
• There are NO USER SERVICEABLE PARTS inside the ModularEasy.
SAFETY INSTRUCTIONS

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Eaton 9PX 5000i RT3U Netpack and is the answer not in the manual?

Eaton 9PX 5000i RT3U Netpack Specifications

General IconGeneral
Power Rating5000 VA / 4500 W
Rack Height3U
Output Frequency50/60 Hz
Output Power Factor0.9
TopologyDouble conversion online
Input Frequency40-70 Hz
Runtime at Half Load11 minutes
DisplayLCD
Form FactorRack/Tower
Output Voltage200/208/220/230/240V
Output ConnectionsIEC C13, IEC C19
Network ManagementYes, via Network Card
Battery TypeSealed Lead Acid
EfficiencyUp to 94%
CommunicationUSB, Serial, Relay
BatteriesInternal
Input Voltage Range176-276 VAC without derating (100-300 VAC with derating)