3. Disassembly and Assembly 01/2018 Rev. 1 EA(B)O-6X06
Transmission Assembly
54. Install the side electro-hydraulic control unit shield.
52. Install the TCU (1) securing it to the bracket with four
Allen screws. Secure the other end of the ground strap
as shown in the gure, using one of the TCU retaining
screws (2).
53. Connect the electrical connector (3) to the TCU.
6939
CAUTION! Observe the correct
procedure for connecting the connector
according to the instructions below.
0002-18
1 - Connect axially
2 - Lock as shown
3 - Do not tilt the connector when connecting
6941
1
2
3
1
2
3

Table of Contents