4. Electro-Hydraulic Control Unit 01/2018 Rev. 1 EA(B)O-6X06
Electro-Hydraulic Control Unit
Disassembly and Assembly
5. Apply 0,5g of Nyogel to each of selection and coupling
electrical connectors and mount then on.
3 Apply 0.4 g of Nyogel to each of the solenoid valves
connectors and mount them on.
4. Apply 1.0g of Nyogel to the electrical motor connector
and plug it on.
0019-18
0018-18
0017-18

Table of Contents