Removal
1. Place the front housing properly supported with
the input shaft bearing cup side up.
2. Use the bearing cup puller E012009 and remove
the bearing cup from the bearing bore.
Input Shaft Bearing Cup
Installation
1. Support properly the front housing with bearing
bore side up.
2. Prior installing the bearing cup, carefully clean
bearing cup and bore.
3. Using the driver and special installer 001013 and
E001015, drive the bearing cup into the bearing
bore until cup seats on the bottom.
5. Install a new expansion plug in the housing hole.
Note:
Refer to “Expansion Plugs” in this manual
for instructions.