Countershaft End Play Measurement
1. Choose one from housing threaded holes and
install the special plate (E009005) to support a
dial indicator with magnetic base.
2. Install one from those removed transmission
capscrews in the hole at countershaft end center.
The capscrew head will be used as a base to set
the dial indicator tip.
3. Rig up some kind of support on the countershaft
to support the pry bar (tool # E008001).
4. Rotate the countershaft several times in both
directions clockwise and counterclockwise to
make sure the countershaft is completely seated
on the bearing.
5. Set the dial indicator tip against the capscrew
head threaded in the countershaft end center. Set
the pointer to zero.
6. Place the pry bar (tool # E008001) under
the countershaft rigged-up support and push
the countershaft upwards at once. Keep the
countershaft in that position while taking the dial
indicator reading. Record that reading.
Determining Shim Pack Thickness for End Play
Adjustment
Specied end play (mm)
Minimum
Maxi-
mum
Remarks
Counter-
shaft
0.06 0.11
Positive
clearance
Mainshaft 0.06 0.11
Positive
clearance
3. Rotate the mainshaft several times in both
directions clockwise and counterclockwise to
make sure the mainshaft is completely seated on
the bearing.
4. Set the dial indicator tip against the mainshaft
end. Set the pointer to zero.
5. Place the pry bar (tool # E008001) under the
mainshaft nut and push the mainshaft upwards
at once. Keep the mainshaft in that position while
taking the dial indicator reading. Record that
reading.