26 |
User Manual
Using the System
26
The current time will replace the hh:mm when editing is complete.
Creating Timed Message Fields
Up to 10 timed messages are allowed per Timed Message field, each associated with a unique time
at which the timed message will appear in the current printer message. In this example, we will set
a timed message to occur at 12 midnight
(zero hours) to read: “Night Shift”.
Press the [F3] key from the EDIT MESSAGE screen to display the SELECT FIELD TYPE menu:
Locate the Timed Message option and press the [enter] key to display the TIMED MESSAGE menu:
Next Message Scroll through existing timed messages (if this field is being edited), or
create an additional timed message if the field is being created for the first
time.
Time Time at which to begin printing timed message.
Message Text to be printed from the time set above. Maximum 20 characters
If several timed messages were created - for example one to start at 10:15, one at 12 noon and another
at 15:00
hours - the first would begin from 10:15 through to 12 noon, the second would print from 12
noon to 15:00 and the third would print from 15:00 to 10:15, and so on.
To create the timed message, use the menu cursor to locate and change the options as shown in
the TIMED MESSAGE menu above. Use a space or separator (/ . : ; , etc.) between the hours and
minutes. Press the [esc] key to return to the EDIT MESSAGE screen:
The message has been inserted where we left the message cursor.
Minimum of Two Timed Messages
One timed message is not enough. Based on this example so far, the system will wait until midnight
before printing the message, which is exactly what we have asked for. However, it will not stop printing
EDIT MESSAGE
F1 2FspaC HGIH 7 Bold Off
F3 4FepyT dleiF Key-Name
VOD PRESSURE PHASE
00000
000
Jet Off 2006-03-24 14:01:38
EJ52
TEST
1
Sell by dd mmm yy
BATCH 9999
hh:mm
SELECT FIELD TYPE
VOD PRESSURE PHASE
00000
000
Jet Off 2006-03-24 14:01:38
Time
> Timed Message
Sequential No.
Date
EJ53
TIME MESSAGE
VOD PRESSURE PHASE
00000
000
Jet Off 2006-03-24 14:01:38
> Next Message
Timed
Message
EJ54
EDIT MESSAGE
F1 2FspaC HGIH 7 Bold Off
F3 4FepyT dleiF Key-Name
VOD PRESSURE PHASE
00000
000
Jet Off 2006-03-24 14:01:38
EJ55
TEST
1
Sell by dd mmm yy
BATCH 9999
hh:mm Night Shift