48 |
48 User Manual
Warning and Fault Messages
Allow the printhead to fully dry before starting the jet.
- Debris or fibres creating a discharge path:
Clean the printhead and check for fibres.
2.02 Charge
This failure occurs when the jet is being started, or when it is running.
Possible causes
- Blocked nozzle or misaligned jet:
Carry out the nozzle clear procedure described in the Troubleshooting section of this manua
(see “roubleshooting - Clearing the Printhead Nozzle”).
- Printhead code or modulation values set incorrectly:
Check the Printhead and Modulation (MOD) values printed on the printhead serial number label
found on the conduit, with the stored values. (see “Changing the System Setup”).
2.03 Velocity Of Ddrop
This failure may occur when the jet is being started.
Possible causes
- Misaligned jet:
Carry out the nozzle clear procedure described in the Troubleshooting section of this manual. (see
“Troubleshooting - Clearing the Printhead Nozzle”).
- Printhead code or modulation values set incorrectly:
Check the Printhead and Modulation values printed on the printhead serial number label
found on the conduit, with the stored values. (see “Changing the System Setup”).
- Build-up of ink on the sensors:
Clean the printhead.
- Blocked filter:
Contact your local EC-JET distributor for assistance.
2.04 300V Power Supply
Possible cause
- The 300 volt power supply output is out of tolerance or has failed:
Call your local EC-JET distributor.
2.05 Temperature/Deflector
A failure has occurred which the printer has not been able to fully identify (see Print Failures “2.00” and
“2.01”).
2.06 Ink Tank Empty
This failure occurs when the ink level sensor has been indicating low for a predetermined time:
Micro 8 hours
Midi 8 hours
Macro 3 hours
This prevents the ink from running out completely if the user fails to top up the ink reservoir following
an “Ink Low” error (see System Warning “3.03”). This failure only occurs when the jet is running since
the jet cannot be started when the ink is low.
2.16 Internal Spillage Fault
This may occur either at switch on, or during normal running. A sensor within the ink system detects
the unwanted presence of ink or solvent within the cabinet tray.