with the help of a screwdriver. The mang plug f
or the 3‑way controller connector is
supplied with the pump.
The connector supplies the power to the vent valve or fan connected to the 3‑pins. The
connector mang plug is shown in Figure: Controller connector showing pin numbers on
page 30, with the polarity of the pins marked, when the vent valve or fan is set to on.
The 24 V d.c. output on the controller connector is protected from the overload or short
circuit to 0 V d.c. / 24 V d.c. Rtn / chassis. The output supplies the current given in Table:
Controller technical data on page 30. For higher currents, the output voltage will
decrease and can set to o to limit the current.
Table 10
Controller technical data
Descripon Data
Connector plug Phoenix part number FK‑MC1881338
Voltage output 24 V d.c. -25%, +10% (18 V d.c. to 26.4 V d.c.)
Current output 500 mA
Figure 8 Controller connector showing pin numbers
Pin number Signal Polarity
1 24 V d.c. Out +
2 Chassis
3 24 V d.c. Rtn -
3.11  Indicator LED's
The  pump has thr
ee indicator LED's, shown in Figure: Controller status informaon on
page 42.
Table 11
Indicator LED’s
LED Descripon
Normal LED
The green LED stays when the rotaonal speed of the pump is more
than the normal speed seng, irrespecve of the acceleraon or
deceleraon of the pump.
Page 30
B85200880_D - Technical data