5.  Con
guraon
WARNING: CONNECTION TO THE VACUUM SYSTEM
Risk of injur
y and damage to equipment. Do not operate the pump if it is not
connected to the vacuum system. The pump rotor rotates at high speeds and the
rotang blades are not visible. If the pump is operated without connecon, the pump
rotor can cause injury.
Before you operate the pump, congure the motor controller sengs that are applicable
for the applicaon.
If the system is designed to operate with parallel control and monitoring, you cannot
change the motor controller sengs when the pump is installed on the system. The
pump is supplied with the sengs at factory default values, as shown in Table: Summary
of commands that can be sent to the nEXT pump on page 47. If you want to change the
motor controller sengs, change the sengs before you install the pump on the system.
To congure the pump, use one of the methods that follows:
▪ Use the customer serial system. Refer to Congure the pump using serial
commands on page 57 for the necessary commands to congure the motor
controller.
▪ Use manufacturer's TIC Turbo and Instrument Controller or TIC Turbo Controller.
R
efer to Conguring the nEXT pump using a TIC on page 62 for more informaon.
Note:
Use the buon on the c
ontroller to adjust the standby speed. Refer to Standby
speed seng on page 59.
If the pump is operated with parallel control and monitoring and the controller sengs
will not be recongured, refer to Before starng the pump on page 64.
5.1  Congure the pump using serial commands
Refer to Table: Summary of commands that can be sent to the pump on page 47 for the
summary of the serial commands, parameter ranges and factory defaults for each
seng. Refer to the secons that follows for more informaon about sengs.
5.1.1  Power limit seng
Table: Power limit seng on page 57 show the power limit seng opons for the pump.
The pump is supplied with a default power limit. If the default power limit is not
applicable for the applicaon, change the default power limit to a value between the
maximum and minimum seng.
Table 18
Power limit seng
Maximum value seng Minimum value seng Default power seng
200 W 50 W 160 W
Page 57
B85200880_D - Con
guraon