4.3.2  Mechanical xing
WARNING: PUMP SEIZURE
Risk of injur
y and damage to equipment. Do not operate the pump unl it is correctly
installed. If the pump seizes, the stored energy of the rotor can cause fast movement
of the pump, which can cause damage and injury to people.
WARNING: INLET SCREEN
Risk of injur
y. The inlet screen is a coarse lter for debris. Do not use the inlet screen
as a nger guard.
WARNING: EJECTED PARTS FROM PUMP
Risk of injur
y and damage to equipment. Posion the system view‑ports and
vulnerable components away from the pump inlet. Failure to do so can cause damage
from the ejected parts if the pump rotor fails.
Obey one of the methods that follows to install the pumps:
▪ Install the pump through its inlet ange to a rigid, rmly xed vacuum system.
Refer to Inlet connecon and orientaon on page 35.
▪ If ins
tallaon of the pump is not possible because of the nature of the vacuum
system, install the base of the pump at a rm support. Refer to Base mounng on
page 35 for instrucons on base mounng the pump.
4.3.3  Inlet connecon and orientaon
The pump can be installed at the vacuum system through the inlet ange. You can
mount the pump in vercal and upright through to horizontal (± 2°). If the pump is
mounted horizontally and used with a rotary vane backing pump, the backing port must
point vercally down (± 20°) to decrease the risk of contaminaon from the backing
pump oil.
Make sure that the pump inlet and the components installed to the pump inlet are clean
and dust‑free. Failure to do so can increase the pump‑down me.
The inlet connecons for the pump are ISO anges:
▪ Use the manufacturer's c
ombinaon inlet screen and trapped O‑ring supplied with
the pump. Use a quanty of 8 M8 bolts to ISO898-1 strength class 12.9 (each
torqued to 20 Nm) to connect the inlet ange of the pump to the vacuum system.
Tighten all inlet ange bolts again when the system is under vacuum. Make sure that
torques or other forces are not transmied to the pump from the vacuum system or the
related pipelines.
4.3.4  Base mounng
The base of the pump can be installed on a rigid support using the tapped xing holes.
Refer to Figure: nEXT200200 dimensions (mm) on page 21 for the installaon hole
details.
Page 35
B85200880_D - Ins
tallaon