Parameter
nXDS
Vibraon: measur
ed at the inlet port (ISO
3744)
Class 1C...< 4.5 mm s
-1
(rms radial)
3.3.2 Construcon
All surfaces of the pump which are exposed to the pumped gases are free from copper,
zinc and cadmium. Exposed components include: anodised aluminium scrolls, aluminium
housing, nickel‑plated inlet and exhaust ports, PTFE composite p‑seals, various
stainless steel parts and uorocarbon elastomer seals.
Other materials of construcon include steel, copper, hydrocarbon lubricant and
chemically resistant polymers.
3.4 Electrical data
Table 8
Electrical rangs for connuous operaon
Pump
Supply (Vac rms) Phase Frequency (Hz) Input current (A rms)
All variants
100 ‑ 127 ± 10% Single 50 - 60 10
200 ‑ 240 ± 10% Single 50 - 60 6
Table 9
Recommended regional supply protecon
Area
Voltage Rang
UK 230 V 10 A, 250 V a.c. rms
Europe 230 V 10 A, 250 V a.c. rms
US 120 V 10 A, 250 V a.c. rms
Japan 100 V 10 A, 250 V a.c. rms
3.4.1 Electrical cables
Recommended cord sets and fuses for regional requirements.
Table 10
Recommended cord sets
Descripon Rang
Coupler type Item number
Cord set
assembly, UK
Cable Style = H05VV‑F
, 3 x 1.0 mm
2
,
300 V, 70 °C, maximum length of
2.0 metres
Straight entry A50505000
Plug Type = BS1363 UK plug
Appliance Coupler = IEC60320 style C14
Fuse Type = BS1363 10 Amp fuse, to an
IE
C60320 style
Cord set
assembly,
Europe
Cable Style = H05VV‑F
, 3 x 1.0 mm
2
,
300 V, 70 °C, maximum length of
2.0 metres
Straight entry A50506000
Page 20
A73501880_G - Technical data