1. Switch o the pump and disc
onnect it from the electrical supply.
2. Use a dry cloth and a so brush to remove dirt and deposits from the fan cover.
6.5 Check the pump performance (service indicator)
The service indicator, (ashing ON 1s / OFF 1s) is triggered as a reminder to check the
performance of the pump. The service indicator will ash to indicate that a pseal
change may be required (based on typical pseal life). If aer checking, the pump is no
longer achieving the required performance, we recommend you to replace a pseal
(refer to Service indicator codes on page 41).
If the pump performance is within acceptable limits, or is performing sasfactorily, the
pseal replacement can be delayed.
If operang a preventave maintenance plan, depending upon the parcular regime, a
pseal change can be carried out at this me irrespecve of the pump performance.
To reset the service indicator, refer to Service indicator codes on page 41.
6.6 Replace the p-seals
This informaon is applicable to the nXDS replacement p seal kit that must be ed.
Refer to Tip-seal kit on page 52 for ordering informaon.
A p-seal replacement should be carried out to maintain or restore the pumps
performance. The frequency for replacing the pump pseals is determine by the
following factors:
The pump has reached a service interval. Refer to Check the pump perf
ormance
(service indicator) on page 40 and Replace the pump bearings (service indicator) on
page 40.
The pump is no longer achieving the required performance.
If the pump is no longer achieving the required performance prior to a service interval
being reached, we recommend you to follow the guide lines, refer to The pump has
failed to achieve the required performance on page 43.
Note:
There may be a running
in period aer ng your new p
seals. The performance
should improve over a period of 24 to 48 hours. If the pump performance does not
improve suciently aer the running
in period, please contact us for advice.
For informaon on how to replace the nXDS pseals and Health and Safety, refer to the
nXDS replacement p seal kit instrucon manual A73502840 which is included on the
CD manual. Also refer to Youtube video at hps://www.youtube.com/watch?
v=vKnh9dxOyhE.
6.7 Replace the pump bearings (service indicator)
The service indicator, (ashing ON 3s / OFF 1s) is triggered to indicate that a bearing
replacement service interval has been reached. Bearing wear cannot necessarily be
detected under normal operang condions. This service interval is a recommendaon
that a bearing replacement is required, this is especially useful if operang a
preventave maintenance plan.
Page 40
A73501880_G - Maintenance

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Edwards nXDS15i and is the answer not in the manual?

Edwards nXDS15i Specifications

General IconGeneral
BrandEdwards
ModelnXDS15i
CategoryWater Pump
LanguageEnglish

Related product manuals