Technical data
M561-00-880 Issue C
Table 9 - Electrical connections
Description Mating Connector description / external supply rating Internal supply rating
Mains connection
Refer to installation section for wiring diagram
Refer to Ta ble 7 for the mains connector fitted to each variant.
Connector is either:
Harting Han® K 4/4-F finger safe
09 38 008 2703, 6-16 mm
2
fine stranded wire
(VDE 0295 class 5, refer to Tabl e 10 ), 8.9mm max insulation diameter
Or
Harting Han® Axial Screw module 100A (2 off required), 09 14 002 2753 10-25 mm
2
or 09 14 002 2751, 16-35 mm
2
fine stranded wire
(VDE 0295 class 5, refer to Tabl e 10 )
Or
Harting Han® Axial Screw module 200A (3 off required), part number of mating
half suitable for 25 - 40 mm
2
wire is 09 14 001 2763 or 09 14 001 2762 for
40 - 70 mm
2
wire. Use fine stranded wire (VDE 0295 class 5, refer to Ta bl e 10)
PDT Interface (front) XLR type 5-way plug 24 V d.c. 0.2 A
System Interface (rear) XLR type 5-way plug 24 V d.c. 0.75 A
*
Ethernet interface
Standard RJ45 type or Neutrik® EtherCon® RJ45 (IEEE802.3i
10 Base T Ethernet)
EMS interface
External emergency stop switch
Pin 1 - supply, Pin 2 - return
Note: If there is no external connection a link
plug must be fitted to operate the pump.
XLR type 6-way plug
24 V d.c. 100 mA
Internal emergency stop switch
Pin 3 - common, Pin 4 - normally open 30 V a.c. 1 A, 60 V d.c. 0.55 A
Comms 24 V supply
Pin 5 - supply, Pin 6 - 0 V supply common
24 V d.c. 0.75 A
*
Chassis