EasyManua.ls Logo

Efka dc 1500 - 11.12 Machine Run Blockage (Safety Switch); 11.14.2 Setting the Speed Limitation Depending on High Lift with the V820 Control Panel

Efka dc 1500
87 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EFKA FP220A5911
61
11.14.3 Setting the Speed Limitation Depending on High Lift with the V810 Control
Panel
! Call parameter 188.
!
Press the E key. "
! Press theF2 key. Actual display. "
! Press the F2 key. Previous values are displayed. "
! Press the F2 key. "
!
Set new value (level) with potentiometer on the machine. "
! Press the F2 key. "
!
Press the E key. New value 08 (upper break point) "
is entered.
!
Press theF2 key. "
!
Set new value (level) with potentiometer on the machine. "
! Press the F2 key. "
!
Press the E key. New value 17 (lower break point) "
is entered.
! Press the P key once. Display of the actual parameter "
number.
or
!
Press the P key twice. Exit programming. "
These values are saved when you start sewing. They remain in effect even after turning the machine off!
Note
If you set a value on the potentiometer, which is between the actual break points, both values will be overwritten when
pressing the E key. Only after that is it possible to program new lower and/or upper break point values.
E
hP [ ° ]
F2
1 1. 3 2 0 0
F2
0 5 1 9
F2
1 1. 3 2 0 0
0 8. 3 2 0 0
F2
0 5 1 9
E
0 8 0 8
F2
0 8. 3 2 0 0
1 7. 3 2 0 0
F2
0 8 0 8
E
0 8 1 7
P
F - 1 8 8
P
F P 2 2 0 A
P

Table of Contents