EasyManua.ls Logo

Efka dc 1500 - Signal Output 512 Impulses Per Rotation; Actuator

Efka dc 1500
87 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EFKA FP220A5911
82
11.42 Signal Output 512 Impulses per Rotation
! Transistor output with open collector
! Signal whenever a generator slot of the position transmitter is sensed
! 512 impulses per rotation of the handwheel
!
Independent of sewing, thus also when turning the handwheel manually
! Suitable e. g. for the connection of a counter
!
An inverted signal is issued at socket ST2/22
11.43 Actuator
The commands for the sewing operation are input by means of the actuator, which is connected to the pedal. Instead of the
built-on actuator another actuator can also be connected to socket B80.
Table: Coding of the Pedal Steps
Pedal step D C B A
-2 H H L L Full heelback (e. g. initiating the seam end)
-1 H H H L Slight heelback (e. g. sewing foot lifting)
0 H H H H Pedal in pos. 0 (neutral)
½ H H L H Pedal slightly forward (e. g. sewing foot lowering)
1 H L L H Speed stage 1 (n1)
2 H L L L Speed stage 2
3 H L H L Speed stage 3
4 H L H H Speed stage 4
5 L L H H Speed stage 5
6 L L H L Speed stage 6
7 L L L L Speed stage 7
8 L L L H Speed stage 8
9 L H L H Speed stage 9
10 L H L L Speed stage 10
11 L H H L Speed stage 11
12 L H H H Speed stage 12 (n2) Pedal fully forward
EB.. Actuator
Function with or without control panel Parameter
Selectable pedal functions (-Pd) 019
Parameter 019 = 0 Pedal in pos. -1 blocked in the seam. But with pedal in pos. -2 sewing foot lifting is possible in the
seam (function active whenever the light barrier is On).
Parameter 019 = 1 With pedal in pos. -1 sewing foot lifting is blocked in the seam.
Parameter 019 = 2 With pedal in pos. -2 thread trimming is blocked (function active whenever the light barrier is On).
Parameter 019 = 3 The functions “pedal in pos. –1” and “pedal in pos. –2” are active.
Parameter 019 = 4 The functions “pedal in pos. –1” and “pedal in pos. –2” are blocked in the seam
(function active whenever the light barrier is On).

Table of Contents