Note
If an input
is active with open contact, the corresponding arrow lights up when the contact is open.
If an input
is
active with closed contact, the corresponding arrow lights up when the contact is closed.
Output Test:
!
Select the desired output by means of the +/- keys
! Enable the selected output by means of the >> key on the V810 or the incorporated control panel
! Enable the selected output by means of the key at the bottom right on the V820
Display Assignment of the outputs
01 Backtacking on socket ST2/34
02 Sewing foot lift on socket ST2/35
03 Output M1 on socket ST2/37
04 Output M3 on socket ST2/27
05 Output M2 on socket ST2/28
06 Output M4 on socket ST2/36
07 Output M5 on socket ST2/32
08 Output M11 on socket ST2/31
09 Output M6 on socket ST2/30
010 Output M9 on socket ST2/25
011 Output M8 on socket ST2/24
012 Output M7 on socket ST2/23
013 Output M10 on socket ST2/29