10.5 The recirculation pump
10.4 The drain pump
Drain pump:
Connection: 230V; 50 Hz; Synchron
Flowrate: 22 L/min
Power: 34W +30%
Resistance: 164W +5/-5%
Pump control (m3):
In order to pump, the appliance must be switched on (b7/DW), the safety level and the floating switch
have to be in empty position. The electronic controls the pump by a triac, depending on the program.
In case of aqua control the floating switch is in full position and the drain pump is active until
the plug is pulled or the water is removed out of the bottom tray.
The appliance would even pump when the appliance is switched on and the safety level (fS) has reacted.
Over-filling protection!
Recirculation pump:
Connection: 230V; 50 Hz; Synchron
Flowrate: 25 L/min
Power: 22W +30%
Resistance: 202W
+5/-5%
Circulation pump control (m22):
The recirculation pump is controled by a triac located on the main electronic board depending on
the program cycle.