Type Designation
- 22 -
9 Type Designation
Additional information about the parameter set (Designation 2):
The parameter set is used to designate devices that are preconfigured at the ELGO Batscale on special custom-
er request 7.1.3. For the standard devices (delivered with an "empty" configuration which is configured by the
customer) the parameter set is P-0000.
NOTE
When ordering, please use the here described ordering code (Type Designation).
Options that are not required are filled in with -.
LIMAX3CP 03000
Designation 1 (example):
Signal Cable Length:
Version:
Resolution:
LIMAX3CP = LIMAX33 CP
(2-channel safety system)
030 = 3.0 m (Standard)
050 = 5.0 m
1000 = 1000 µm = 1.00 mm at delivery state*
* Freely configurable according to CiA 406
Interface:
---
00 = Standard version
01 = 1. special version (etc.)
- 1000 CO0TG
COX = CANopen [special protocol separately defined by version number]
CO0TG = CANopen [Encoder Profil DS406]
CO1TG = CANopen [Elevator Profil DS417 on request]
NOTE:
-> The CAN interface is with 120R terminated ( T ) and galvanically isolated ( G )
0
Floor Sensors:
P-0001
CAN Bitrate:
P-XXXX = Parameter set (will be defined by the customer)
125k = 125 kbps
250k = 250 kbps
500k = 500 kbps
/
250k
0 = no floor sensor
1 = 1 floor sensor
2 = 2 floor sensors
SR - relay pairs:
0 = no SR - relay pair
1 = 1 SR - relay pair
2 = 2 SR - relay pairs
-
Series / Type:
Designation 2 (example):
/
/
1
eSGC - actuator:
0 = without eSGC
1 = with eSGC
0