Insulation Voltage: 250V
Range Resolution Accuracy
2.000 MΩ 0.001 MΩ ±(5% of reading + 10 digit)
20.00 MΩ 0.01 MΩ ±(10% of reading + 3 digit)
200.0 MΩ 0.1 MΩ ±(20% of reading + 3 digit)
Insulation Voltage: 500V
Range Resolution Accuracy
2.000 MΩ 0.001 MΩ ±(5% of reading + 10 digit)
20.00 MΩ 0.01 MΩ ±(5% of reading + 3 digit)
200.0 MΩ 0.1 MΩ ±(5% of reading + 3 digit)
500 MΩ 1 MΩ ±(10% of reading + 3 digit)
Insulation Voltage: 1000V
Range Resolution Accuracy
2.000 MΩ 0.001 MΩ ±(5% of reading + 10 digit)
20.00 MΩ 0.01 MΩ ±(5% of reading + 3 digit)
200.0 MΩ 0.1 MΩ ±(5% of reading + 3 digit)
1000 MΩ 1 MΩ ±(10% of reading + 3 digit)
3.6.
+200mA Continuity and +200mA / -200mA Low Ohm (EN61557-4)
Warning: Measure only on equipment and circuits that is de-energized!
Open-circuit voltage ................................................................................... 6.0Vd.c.
Measuring current ....................................................................................... min. 200mA, load resistance < 1Ω
Test lead compensation.............................................................................. < 5Ω
Continuity sound output resistance ............................................................. < 2Ω, < 5Ω, < 10Ω, < 20Ω
< 50Ω, < 100Ω
The number of possible tests ...................................................................... ~1700
Range Resolution Accuracy
20.00 Ω 0.01 Ω ±(3% of reading + 3 digit)
200.0 Ω 0.1 Ω
±(5% of reading + 3 digit)
2000 Ω 1 Ω
The test result may be adversely affected by impedances of additional operating circuits connected in parallel or by
transient currents.