TelevisGo Page 55/68
7.3.1 PARAMETERS
IMPORTANT: A parameter map is not available for all devices.
This function is not available for these devices.
To Read and Write the parameters of individual devices, go to:
Functions Parameters
The following screen opens:
Page last update on: 7.39.34
Expand all Collapse all Cancel filters
LAN Adapter
Interface
ID Protocol
0
Micronet
Address
192.168.0.1
Fieldbus
LanAdapter
Address DescriptionName (short)
02:00 0.02:00 ID 974LXID 974LX
Compact
999
BusAdapterN/A
Address DescriptionName (short)
02:01 0.02:01 ID 974LXIC 974LX
Filter devices
Description
A
B
C
D
E
The following controls will be visible:
• (A) Device filters, to filter by device description.
(B) View list of network devices grouped by interface.
(E) Expand/hide devices in an interface.
Devices can be selected using the relative radio button to the left of the address (C).
Only one device can be selected at a time.
The following buttons are presented at the top (F):
Expand all: to view the devices of all interfaces in the list.
Collapse All: to hide the devices of all interfaces in the list.
Cancel Filters: to restore the display of all devices and cancel device filters.
Click
to go to the next page. This screen shows all parameters of the selected device:
SEt Regulation set point °C/°F LSE() HSE() -2.4
diF Tripping differential °C/°F 0.1 30.0 0.3
HSE Maximum value settable for set point °C/°F LSE() 302.0 -1.0
LSE Minimum value settable for set point °C/°F -58.0 HSE() -2.4
OSP Offset on set point °C/°F -30.0 30.0 0.0
Cit Minimum enabling time for compressor output min 0 250 0
CAt Maximum enabling time for compressor output min 0 250 0
dOd Loads shutdown enabling after door micro enabling flag 0 1 0
dAd Enabling delay of digital inputs min 0 255 0
Ont ON time for compressor output with faulty regulation probe min 0 250 10
OFt OFF time for compressor output with faulty regulation probe min 0 250 3
dOn Compressor output enabling delay from request s02500
dOF Compressor output enabling delay from shutdown min 0 250 3
dbi Delay between two consecutive starts of the compressor output min 0 250 0
OdO Delay output enabling from Power On min 0 250 0
dty Type of defrost flag 0 2 0
dit Interval between defrosts h/min/s 0 250 8
dt1 Unit of measurement for defrost intervals flag 0 2 0
dt2 Unit of measurement for defrost duration flag 0 2 1
dCt Defrost interval count mode flag 0 2 1
dOH Defrost cycle enabling delay from request min 0 59 59
Time interval
Address: 0.02:00
Description: ID 974LX
Name:
Group
Label
Description
Checked rows
Unchecked rows
Empty values
Filled values
Valid data
Invalid or missing values
Read/write
Read only
Parameter filters
Legend
Load parameter map
Label Description UM Min Max Default Device Input